Aquifer Characteristics Database Detail

DWR Aquifer Characteristics Detail for ENR Morgans Corner RS
FieldData
CountyPasquotank
Latitude36.431549
Longitude-76.375628
Location AccuracyGPS Show Map
Quad link to wellsC 12W1
Name link to logsENR Morgans Corner RS
SourceNorth Albemarle Report
Land Surface 9.71
Depth 1.00
Top Test Zone 27.00
Bottom Test Zone 37.00
Diameter (inches) 2.50
AquiferSurficial
Data SourceObservation Well
Test TypeMultiple Well Test
Test Date
Test Duration (minutes) 240
Pumping Rate (gallons/minute) 17.15
Static Water Level (feet below land surface)
Yield (gallons/minute) 30
Specific Yield (percentage)
Specific Capacity (gallons/minute per foot)
Hydraulic Conductivity (feet per day) 124.30
Vertical Hydraulic Conductivity
or K-Prime (feet per day)
124.30
Transmissivity (square feet per day) 2,487.00
Storage Coefficient 0.000054
Analysis MethodTheis
Comments

Monitoring well ids, depths, and screened intervals at this location. Wells are links to hydrograph data. i -- indicates an inactive well