NC Division of Water Resources

Aquifer Characteristics Database Detail

DWR Aquifer Characteristics Detail for Town of Windsor Test Well
FieldData
CountyBertie
Latitude36.005020
Longitude-76.948200
Location AccuracyGPS Show Map
QuadH 19V
Name link to logsTown of Windsor Test Well
SourceGroundwater Management Associates
Land Surface 17.00
Depth 112.00
Top Test Zone 77.00
Bottom Test Zone 107.00
Diameter (inches) 6.00
AquiferCastle Hayne
Data SourcePumping Well
Test TypeSingle Well Test
Test Date2010-03-17
Test Duration (minutes) 360
Pumping Rate (gallons/minute) 198.80
Static Water Level (feet below land surface)
Yield (gallons/minute) 199
Specific Yield (percentage)
Specific Capacity (gallons/minute per foot) 4.19
Hydraulic Conductivity (feet per day) 26.80
Vertical Hydraulic Conductivity
or K-Prime (feet per day)
Transmissivity (square feet per day) 1,340.00
Storage Coefficient
Analysis MethodJacob Time Drawdown
Comments